Potter EVD-1 User Manual

Browse online or download User Manual for Safety Potter EVD-1. Potter EVD-1 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
EVD-1 Controller
RTA (optional)
Manual #5401043 - Rev N
6/09
POTTER ELECTRIC SIGNAL COMPANY, LLC
St. Louis, MO
(866) 956-1211 • (314) 595-6900 • FAX (314) 595-6999
www.pottersignal.com
EVD-1
Electronic Vibration
Detector System
Installation, Operation, and
Instruction Manual
(All speci cations subject to revision.)
Page view 0
1 2 3 4 5 6 ... 14 15

Summary of Contents

Page 1 - Instruction Manual

EVD-1 ControllerRTA (optional)Manual #5401043 - Rev N6/09POTTER ELECTRIC SIGNAL COMPANY, LLCSt. Louis, MO (866) 956-1211 • (314) 595-6900 • FAX (314)

Page 2 - WARRANTY INFORMATION

10EVD-1 • 5401043 • REV M • 9/07Optional Control Panel Wiring With Safe Detector Zone Only (4 Conductor Shielded Cable Required)Figure 3c

Page 3 - CONTENTS

11EVD-1 • 5401043 • REV M • 9/07Sensitivity Adjustments1. Adjust the EVD-1’s internal pickup sensitivity control, RV1, to 1/2 scale (12 o’clock posit

Page 4

12EVD-1 • 5401043 • REV M • 9/07Recommended Detector LocationsSingle Detector ApplicationsAll safe applications must have at least one EVD-1 on the bo

Page 5

13EVD-1 • 5401043 • REV M • 9/07Note: D=Maximum Linear Distance *Steel Safe Construction: Body: Minimum 1/4" Steel Door: Minimum 1

Page 6 - DWG# 1043-2

14EVD-1 • 5401043 • REV M • 9/07Height (inches)Depth (inches)Width (inches)12 12 1212 18 1812 24 1812 24 2418 12 1218 18 1818 24 1818 24 2424 12 1224

Page 7

15EVD-1 • 5401043 • REV M • 9/07Figure 8 Typical Wall Protection InstallationCIRCULAR AREA OF 100% COVERAGERECTANGULAR AREA OF 100% COVERAGEDETECTOR

Page 8 - WIRE FOR

2EVD-1 • 5401043 • REV M • 9/07POTTER ELECTRIC SIGNAL COMPANY, LLCSt. Louis, MO • (866) 956-1211 • (314) 595-6900 • FAX (314) 595-6999 • www.pottersig

Page 9 - Complete Installations)

3EVD-1 • 5401043 • REV M • 9/07CONTENTSGeneral Information 5Features 5Specifi cations 5Ordering Information 5EVD

Page 10 - Figure 3c

4EVD-1 • 5401043 • REV M • 9/07

Page 11

5EVD-1 • 5401043 • REV M • 9/07 General InformationThe EVD-1, Electronic Vibration Detector, is listed by Underwriters Laboratories, Inc. and Underwri

Page 12

6EVD-1 • 5401043 • REV M • 9/07Figure 1. EVD-1 Controller DetailsEVD-1 ControllerThe EVD-1 controller is a microprocessor controlled, vibration dete

Page 13

7EVD-1 • 5401043 • REV M • 9/07EVD-1 Terminal ConnectionsTerminal Terminal Description No. Name 1 (+) Power Supply Connection, +12 VDC nominal (Se

Page 14

8EVD-1 • 5401043 • REV M • 9/07Recommended Control Panel Wiring andRemote Test and Annunciator ConnectionsFigure 3aInstallationThe EVD-1 System must b

Page 15 - All dimensions in inches

9EVD-1 • 5401043 • REV M • 9/07Recommended Control Panel Wiring With Safe Detector Zone And 24 Hour Alarm (High Security "B" Cable Required

Comments to this Manuals

No comments